Next-Generation Ceramics: Unlocking Superior Properties for Industry
PRODUCT PARAMETERS
Description
Overview of Alumina Ceramic TGA Crucible With Lid For Testing Instrument Use
A Ceramic Crucible is a vessel designed to withstand extreme temperatures for melting, calcining, or reacting chemical substances. Advanced ceramic crucibles are engineered from high-purity materials like Alumina, Zirconia, Boron Nitride, or Magnesia, chosen for their ability to contain specific molten materials without contamination or failure.
Features of Alumina Ceramic TGA Crucible With Lid For Testing Instrument Use
- Extreme Temperature Resistance: Can operate continuously from 1000°C to over 1800°C, depending on the material.
- High Purity & Chemical Inertness: Minimizes reaction with and contamination of the melt (metal, glass, salt, ash).
- Excellent Thermal Shock Resistance: (Grade-dependent) Can withstand rapid heating and cooling cycles.
- Variety of Compositions & Designs: Tailored for specific applications (e.g., BN for reactive metals, ZrO₂ for precious metals, MgO for basic slags).
- Durable & Reusable: High-quality crucibles can survive multiple cycles, providing long service life.

Specifications of Alumina Ceramic TGA Crucible With Lid For Testing Instrument Use
Alumina Ceramic TGA Crucible with Lid – Precision for Thermal Analysis
Material and Build Quality
This crucible is made from high-purity alumina ceramic. The material offers excellent resistance to heat, corrosion, and thermal shock. It stays stable even at temperatures up to 1700°C (3092°F). The dense structure prevents sample contamination and ensures consistent test results.
Design Features
The crucible comes with a matching lid. This helps control the atmosphere around your sample during testing. Both crucible and lid have smooth inner surfaces. This makes cleaning easier and reduces residue buildup. The shape is optimized for uniform heating in thermogravimetric analyzers (TGA).
Standard Sizes and Compatibility
Available in common lab sizes like 50 µL, 100 µL, and 150 µL volumes. These dimensions fit most standard TGA instruments from major brands. Always check your instrument’s manual to confirm compatibility before use.
Precision and Performance
Each crucible is manufactured to tight tolerances. Wall thickness and height are kept uniform across batches. This consistency supports accurate weight measurements during thermal analysis. The high purity of the alumina (≥99.5%) minimizes interference with sensitive readings.
Handling and Care
Handle with clean ceramic or metal tongs to avoid surface damage. Do not subject the crucible to sudden temperature changes. Preheat gradually when used above 1000°C. Clean gently with soft brushes or ultrasonic baths. Avoid strong acids unless absolutely necessary.
Key Benefits:
– Works reliably at very high temperatures
– Resists chemical attack from most lab reagents
– Ensures repeatable, clean test conditions
– Compatible with standard TGA equipment
Use this alumina ceramic crucible when you need dependable performance in demanding thermal testing environments.

Applications of Alumina Ceramic TGA Crucible With Lid For Testing Instrument Use
Alumina Ceramic TGA Crucible with Lid – Precision for Thermal Analysis
High-Temperature Stability You Can Trust
This alumina ceramic crucible is built for thermal gravimetric analysis (TGA) instruments. It handles extreme heat without cracking or warping. The material stays stable even above 1600°C. That makes it ideal for labs running high-temperature tests.
Why choose this crucible?
Pure alumina offers excellent chemical resistance. It won’t react with most samples, even aggressive ones like metals, oxides, or salts. This keeps your test results clean and accurate. The tight-fitting lid helps control the atmosphere inside during heating. It also reduces sample loss from splattering or evaporation.
Designed for Real Lab Use
The crucible has a smooth interior surface. This prevents residue buildup and makes cleaning easier. Its shape fits standard TGA instrument holders. No need to adjust your setup—just place it in and start testing.
Each unit is made with consistent wall thickness. That ensures even heat distribution. Uneven heating can skew weight measurements. With this crucible, you get reliable data run after run.
Durable and reusable
Unlike cheaper alternatives, this alumina crucible lasts through many cycles. It resists thermal shock when heated or cooled quickly. That means fewer replacements and lower long-term costs.
Labs use it for material research, quality control, and failure analysis. It works well with polymers, ceramics, composites, and more. Whether you’re measuring moisture content, decomposition points, or ash residue, this crucible delivers dependable performance.
Handle it with standard lab tongs. Store it in a dry place when not in use. Avoid sudden temperature swings outside the instrument to keep it in top condition.
Company Profile
Synthetic-chemical focus on the research and development, production and sales of ceramic products, serving the electronics, ceramics, chemical and other industries. Since its establishment in 2015, the company has been committed to providing customers with the best products and services, and has become a leader in the industry through continuous technological innovation and strict quality management.
Our products includes but not limited to Aluminum Nitride, Aluminum Oxide, Boron Carbide, Boron Nitride, Ceramic Crucible, ect. If you are interested in any type of these, please feel free to contact us.

Payment Methods
T/T, Western Union, Paypal, Credit Card etc.
Shipment Methods
By air, by sea, by express, as customers request.

5 FAQs of Alumina Ceramic TGA Crucible With Lid For Testing Instrument Use
Frequently Asked Questions About Alumina Ceramic TGA Crucibles with Lid
What is this crucible made of?
This crucible is made from high-purity alumina ceramic. Alumina offers excellent heat resistance and chemical stability. It can handle temperatures up to 1700°C without deforming or reacting with most samples.
Why does it come with a lid?
The lid helps control the sample environment during testing. It reduces contamination from outside air. It also limits sample loss due to evaporation or splattering, especially for powders or volatile materials.
Can I reuse this crucible?
Yes, you can reuse it if handled properly. After each use, clean it gently with distilled water or mild solvents. Avoid sudden temperature changes. Do not use abrasive tools that may scratch or weaken the ceramic.
Is it compatible with my TGA instrument?
Most standard TGA instruments accept alumina crucibles of common sizes (like 70 µL or 100 µL). Check your instrument’s manual for exact dimensions and material compatibility. Alumina is widely accepted because it stays inert under typical test conditions.
How should I store the crucible when not in use?
Store it in a clean, dry place. Keep it in its original packaging or a dust-free container. Make sure no moisture or debris gets inside. This helps maintain accuracy and prevents unexpected reactions during future tests.
REQUEST A QUOTE
RELATED PRODUCTS
Dental Crucible For Casting Metal Ceramic Dental Lab Porcelain
Alumina Ceramic Aluminum Oxide Crucible for Laboratory Applications
Custom Aluminum Nitride Ceramic Oil Cup Crucible for Special Applications
Customizable High Temperature Al2O3 Alumina Ceramic Crucible OD10 ID8 60mm
Best ing Alumina Ceramic Crucible for Melting Use Various Sizes